Specifications
Specifications
- Operating Temperature
- −40 to 70 °C
- Operating Temperature
- −40 to 158 °F
- Relative Humidity
- 0% to 90%, Noncondensating
- Control Relay Type
- Double-Pole, Solid-State; Double-Pole, Mechanical
- Control Max Voltage
- 690 VAC Nominal, 50/60Hz
- Control Max Current
- 63A @ 40°C
- Control Algorithms
- On/Off, Proportional, PASC, Always On, Always Off
- Temperature Control Range
- −200 to 700 °C
- Temperature Control Range
- −328 to 1292 °F
- Temperature Alarm
- −200 to 700 °C
- Temperature Alarm
- −328 to 1292 °F
- Ground Fault Alarm
- 10 – 500 mA
- Current Alarm
- 0.1 – 100 A
- Voltage Alarm
- 80 – 300 V
- Autocycle
- 1 – 750 h
- Max Power Supply Input Wire Size
- 16.8 mm²
- Max Power Supply Input Wire Size
- #5
- Max Heating Cable Output Wire Size
- 16.8 mm²
- Max Heating Cable Output Wire Size
- #5
- Max Ground Terminal Wire Size
- 16.8 mm²
- Max Ground Terminal Wire Size
- #5
- Communication
- RS-485; Ethernet
- Communication Protocol
- Modbus RTU; Modbus/TCP
- RS-485 Cable Type
- One 2-Wire, Shielded Twisted Pair
- Ethernet
- 10/100 Base-T
Catalog Number
|
Item Name
|
Safety Limiter
|
Intrinsically Safe Barries on RTD Inputs
|
---|---|---|---|
10380-021 | 4020i-MOD-IS | No | Yes |
10380-020 | 4020i-MOD | No | No |
Specifications
- Operating Temperature
- −40 to 70 °C
- Operating Temperature
- −40 to 158 °F
- Relative Humidity
- 0% to 90%, Noncondensating
- Control Relay Type
- Double-Pole, Solid-State; Double-Pole, Mechanical
- Control Max Voltage
- 690 VAC Nominal, 50/60Hz
- Control Max Current
- 63A @ 40°C
- Control Algorithms
- On/Off, Proportional, PASC, Always On, Always Off
- Temperature Control Range
- −200 to 700 °C
- Temperature Control Range
- −328 to 1292 °F
- Temperature Alarm
- −200 to 700 °C
- Temperature Alarm
- −328 to 1292 °F
- Ground Fault Alarm
- 10 – 500 mA
- Current Alarm
- 0.1 – 100 A
- Voltage Alarm
- 80 – 300 V
- Autocycle
- 1 – 750 h
- Max Power Supply Input Wire Size
- 16.8 mm²
- Max Power Supply Input Wire Size
- #5
- Max Heating Cable Output Wire Size
- 16.8 mm²
- Max Heating Cable Output Wire Size
- #5
- Max Ground Terminal Wire Size
- 16.8 mm²
- Max Ground Terminal Wire Size
- #5
- Communication
- RS-485; Ethernet
- Communication Protocol
- Modbus RTU; Modbus/TCP
- RS-485 Cable Type
- 2-Wire One Shielded Twisted Pair
- Ethernet
- 10/100 Base-T
Catalog Number
|
Item Name
|
Safety Limiter
|
Intrinsically Safe Barries on RTD Inputs
|
---|---|---|---|
10380-024 | 4020i-MOD-3P-IS | No | Yes |
10380-022 | 4020I-MOD-IS-LIM | One Dedicated Temperature Input | Yes |
10380-023 | 4020i-MOD-3P | No | No |
Specifications
- Operating Temperature
- −40 to 70 °C
- Operating Temperature
- −40 to 158 °F
- Relative Humidity
- 0% to 90%, Noncondensating
- Control Relay Type
- Double-Pole, Solid-State; Double-Pole, Mechanical
- Control Max Voltage
- 690 VAC Nominal, 50/60Hz
- Control Max Current
- 63A @ 40°C
- Control Algorithms
- On/Off, Proportional, PASC, Always On, Always Off
- Temperature Control Range
- −200 to 700 °C
- Temperature Control Range
- −328 to 1292 °F
- Temperature Alarm
- −200 to 700 °C
- Temperature Alarm
- −328 to 1292 °F
- Ground Fault Alarm
- 10 – 500 mA
- Current Alarm
- 0.1 – 100 A
- Voltage Alarm
- 80 – 300 V
- Autocycle
- 1 – 750 h
- Max Power Supply Input Wire Size
- 16.8 mm²
- Max Power Supply Input Wire Size
- #5
- Max Heating Cable Output Wire Size
- 16.8 mm²
- Max Heating Cable Output Wire Size
- #5
- Max Ground Terminal Wire Size
- 16.8 mm²
- Max Ground Terminal Wire Size
- #5
- Communication
- RS-485; Ethernet
- Communication Protocol
- Modbus RTU; Modbus/TCP; PROFIBUS
- RS-485 Cable Type
- 2-Wire One Shielded Twisted Pair
- Ethernet
- 10/100 Base-T